The 3-EVF-200 6V200Ah is a 6-volt, 200 amp-hour sealed valve-regulated AGM lead-acid block designed for mid-to-large electric road vehicles: 4-8 seat sightseeing vehicles, golf carts, 1-3 ton electric forklifts and stackers, floor scrubbers and sweepers, AGV robots and small electric boats. It is the 6 V member of the EVF traction range, and its 200 Ah rating is a 3-hour rate at a 1.75 V per cell cutoff — not a 20-hour figure.
Five numbers decide the procurement:
- 200 Ah at C3 (3-hour rate), cutoff 1.75 V per cell. A 20-hour rating for the same block is materially lower, and sellers who quote one and compare it against the other create a battery that underperforms in the middle of a shift.
- 260 x 180 x 270 mm, 275 mm over the terminals, 34 kg per unit. Eight units in series make a 48 V pack that weighs 272 kg.
- 40 A maximum charging current and float 6.75 V / equalise 7.05 V for the 6 V block. The charger and the controller profile must match this voltage band exactly.
- 350-600 cycles at 50-80% depth of discharge, with a 2-5 year design life and a -15 °C to +50 °C working window.
- Sealed construction with no water or acid refill, which means no service visits, but also means the end of life arrives as a block replacement rather than a gradual capacity loss you can measure in the field.
The honest caveat: the 3-EVF-200 6V200Ah is a traction cell with a stationary charging profile (6.75 V float, 7.05 V equalise, 40 A). If your vehicle runs a daily deep-discharge cycle with a BMS-controlled lithium pack, the comparison changes; §3 shows exactly where the boundary sits.
Key Takeaways
- The rating basis is the whole argument. 3-EVF-200 6V200Ah means 200 Ah at C3 with a 1.75 V per cell cutoff. Insist on the C3 definition in the warranty, because a 20-hour seller figure for the same case is a different product.
- Pack arithmetic decides the configuration, not habit. Eight 3-EVF-200 units give a 48 V bus, 10-12 units give 60-72 V for heavier forklift and stacker classes, and 8-16 units cover the 48-96 V band. Each step up in voltage adds units, weight and terminals.
- Energy per pack is the number to compare. Eight 3-EVF-200 units in a 48 V pack deliver 9.6 kWh nominal (8 x 6 V x 200 Ah); a smaller block in the same voltage class can be beaten on energy while using the same unit count.
- Charging is a hard limit, not a recommendation. 40 A per unit means an eight-unit 48 V pack wants a charger in the 320 A class, with a 6.75 V float and 7.05 V equalise stage controlled to the vehicle profile.
- Temperature and storage discipline matter more than in warmer markets. The published window is -15 °C to +50 °C, and a battery shipped through a hot port or stored through a dry season needs the 12-hour initial charge before it goes into service.
§1 — 3-EVF-200 6V200Ah Quick Specifications Table
The published 3-EVF-200 6V200Ah data sheet is the basis for every number below. The full factory page for this block is at the 3-EVF-200 product page.
| Parameter | Published value for 3-EVF-200 |
|---|---|
| Model | 3-EVF-200 |
| Nominal voltage | 6 V |
| Capacity | 200 Ah at the 3-hour discharge rate (C3), cutoff 1.75 V/cell |
| Dimensions (L x W x H) | 260 x 180 x 270 mm |
| Total height over terminals | 275 mm |
| Weight | 34 kg (+/- 0.2 kg) |
| Terminal | phi20-M8 |
| Technology | Valve-regulated lead-acid, AGM (VRLA) |
| Cycle life | 350-600 cycles at 50-80% depth of discharge |
| Float voltage | 6.75 V |
| Equalise charge voltage | 7.05 V |
| Maximum charging current | 40.0 A |
| Working temperature | -15 °C to +50 °C |
| Design lifespan | 2-5 years |
| Maintenance | Maintenance-free; no water or acid refilling |
| Initial charge | New or long-idle batteries require an initial charge of not less than 12 hours |
| System configuration | 8 units in series for 48 V; 10-12 units for 60-72 V; 8-16 units for 48-96 V |
| Typical applications | Electric sightseeing vehicles (4-8 seats), golf carts, electric forklifts and stackers (1-3 ton), floor scrubbers and sweepers, AGV robots, electric boats |
§2 — The Pain
The failure mode in this category is not dramatic. It is a battery that arrives correctly, passes a workshop charge test, and then leaves a vehicle short of range in the middle of a working day. The causes are always the same three, and all three start with a specification that nobody pinned down.
The rating basis is assumed rather than stated. A buyer asks for “6 volt 200 amp-hour” and receives a block that satisfies 200 Ah at the 20-hour rate. That block is a different product from the 3-EVF-200 6V200Ah, which delivers 200 Ah at C3. On a vehicle that pulls a high current for a few hours per shift, the 20-hour-rated block looks fine on the datasheet and then shows a shorter working window than the operator expects. The procurement problem is that nothing in the purchase order says which basis applies, so nobody can hold the supplier to a number.
The charge controller is specified separately from the battery. A 6 V block floats at 6.75 V and equalises at 7.05 V. A charger programmed for a different chemistry or a different voltage band will trickle at the wrong voltage, will not complete an equalise stage after a deep discharge, and will age the block faster than the published cycle life assumes. For an unattended or leased fleet this happens quietly, because the vehicle still runs.
Pack configuration is inherited from a previous model. Eight units at 6 V and four units at 12 V both make a 48 V pack, and both are quoted as “48 V”. The unit count changes the mechanical envelope, the interconnect count, the service procedure and the failure surface: eight units means eight sets of terminals and eight potential points of thermal stress.
There is a fourth, quieter problem. Storage. A 6 V block that has been in a container at Jebel Ali or Santos through a hot season, or that has sat in a distributor warehouse in Dubai, arrives with a partial state of charge and a surface charge that looks like a full battery. The published instruction is not negotiable: the first charge after transit or after long idle storage should run not less than 12 hours before the vehicle goes into service.
§3 — The Choice
3-EVF-200 6V200Ah is the right block when the vehicle runs a 48 V bus, the duty is deep daily discharge, and the site has no maintenance capability. The pack arithmetic is published, and so is everything you need to check it against:
| Pack configuration | Units | Bus voltage | Capacity basis | Nominal energy (arithmetic) | Pack weight (arithmetic) | Charge current (arithmetic) | Where it fits |
|---|---|---|---|---|---|---|---|
| 48 V pack | 8 | 48 V | 200 Ah at C3 | 8 x 6 V x 200 Ah = 9.6 kWh | 8 x 34 kg = 272 kg | 8 x 40 A = 320 A | Golf carts, 4-8 seat sightseeing vehicles, scrubbers |
| 60 V pack | 10 | 60 V | 200 Ah at C3 | 10 x 6 V x 200 Ah = 12.0 kWh | 10 x 34 kg = 340 kg | 10 x 40 A = 400 A | Light forklift and stacker classes |
| 72 V pack | 12 | 72 V | 200 Ah at C3 | 12 x 6 V x 200 Ah = 14.4 kWh | 12 x 34 kg = 408 kg | 12 x 40 A = 480 A | 1-3 ton electric forklifts and stackers |
| 96 V pack | 16 | 96 V | 200 Ah at C3 | 16 x 6 V x 200 Ah = 19.2 kWh | 16 x 34 kg = 544 kg | 16 x 40 A = 640 A | Heavy-load duties and extended-runtime AGVs |
These are arithmetic consequences of published 3-EVF-200 figures, not lab results. They are the numbers you use to check a supplier’s quote against your own floor space and your own charger bay.
Where the 3-EVF-200 loses is cycle life against a lithium traction pack, and that comparison should be made honestly. Published cycle figures for quality lead-acid AGM fall in the 400-800 cycle band at 80% depth of discharge, and the 3-EVF-200 sits at the lower end of that band at 350-600 cycles for 50-80% depth of discharge, which is consistent with the 2-5 year design life. Comparable LFP traction chemistries publish 3,000-5,000 cycles at 80% depth of discharge. A fleet that cycles the pack twice a day on a fixed route will consume lead-acid packs years earlier than an LFP pack would be retired. A fleet that cycles once a week, keeps the pack on shore power between shifts, or runs seasonal operations will not.
The cost side follows the same logic. A modelled 7-year ownership comparison for a 48 V, 600 Ah class traction pack, using typical industrial pricing, shows where the crossover sits:
| Cost item | Conventional lead-acid pack | LFP pack | Basis |
|---|---|---|---|
| Initial purchase | USD 4,000 | USD 9,500 | Lead-acid requires multiple sets over the horizon, LFP one set |
| 7 years of charging energy | USD 6,500 | USD 3,800 | LFP charge efficiency roughly 20-25% higher |
| 7 years of maintenance labour | USD 4,200 | USD 0 | Lead-acid requires watering and equalising |
| 7 years of battery replacement | USD 8,000 | USD 0 | Lead-acid needs roughly two replacements in 7 years |
| Downtime (modelled) | USD 3,000 | USD 800 | Lead-acid failure rate higher |
| 7-year total | USD 25,700 | USD 14,100 | LFP roughly 45% lower in this model |
The modelled figure depends on local energy prices, labour rates and duty cycles, so treat it as a structure rather than a quotation. For a high-cycle operation the lead-acid line stays above the lithium line for most of its life. For a low-cycle or standby-heavy operation, and for any site without a technician, the sealed 3-EVF-200 block wins on cost and on logistics.
3-EVF-200 6V200Ah is better than a 12 V block in the same traction class because it halves the unit count at 48 V (8 units instead of 4 at 12 V for the same bus voltage, each with roughly double the cell count inside), which means fewer enclosures, fewer interconnects and fewer water points of failure. It is better than an open flooded block because the 3-EVF-200 needs no watering interval in a hot climate, and better than a generic VRLA block because the C3 rating basis and the published 40 A charge limit are stated rather than inferred.
If your application runs a deep-cycle marine duty with heavy vibration, review the full EVF range before you commit: the EVF series overview sets out the voltage and capacity ladder the 3-EVF-200 sits in, including the 8 V and 12 V members used for 24 V and 48 V builds.
§4 — The Framework
Seven criteria decide whether the 3-EVF-200 6V200Ah is the correct block for a specific vehicle. Use them in order, because each one eliminates a class of mistake that the next one cannot fix.
- Confirm the rating basis. The block is rated 200 Ah at C3 to a 1.75 V per cell cutoff. If the supplier’s datasheet shows a 20-hour rating, you are looking at a different cell. Write the basis into the purchase order.
- Fix the bus voltage and count the units. 8 units for 48 V, 10-12 for 60-72 V, 8-16 for the 48-96 V band. Add the arithmetic energy and weight to your layout, and check that 272 kg for an eight-unit pack still fits the battery tray with the service clearance you need.
- Size the charger for the pack, not for one unit. The published maximum of 40 A per 3-EVF-200 unit means an eight-unit pack sits in the 320 A class. A smaller charger lengthens every charge cycle and the equalise window after a deep discharge.
- Match the controller voltage band. 6.75 V float and 7.05 V equalise for the 6 V block, with the 7.05 V equalise stage properly timed and temperature-compensated.
- Check the temperature window against the deployment reality. -15 °C to +50 °C covers most sheltered sites in Mumbai, Durban, Ho Chi Minh City and Jakarta; a vehicle parked in direct sun in a non-air-conditioned bay in the Gulf or northern India can exceed the published charge ceiling during an equalise cycle.
- Plan the initial charge. Not less than 12 hours for a new block or one that has been stored or shipped long. This applies to every block that has crossed an ocean in a container through Mombasa, Santos, Port Said or Jebel Ali.
- Standardise on one block across the fleet. Mixing capacities inside a pack set is the most common cause of the early failures the manufacturer never sees. If you are standardising an AGV or forklift fleet, the AGV battery programme and the AGM and front-terminal range are the reference for the rest of the pack.
§5 — The Trust
The 3-EVF-200 6V200Ah is a straightforward industrial block, and straightforward products are exactly where procurement shortcuts accumulate. Before you sign, work through this list.
Ask for the test basis, not the headline number. A published “350-600 cycles” figure for the 3-EVF-200 means cycles at 50-80% depth of discharge under a defined test profile. Ask which depth of discharge the lower and upper figures refer to, at what cutoff voltage, and at what temperature. A supplier who cannot answer that in one email is telling you something useful.
Confirm the charge limit in writing. 40 A is a published maximum for the block. If your charger program exceeds it, the warranty position is yours, not the supplier’s. Any claim that a charger can be set to 0.3C on this block should be checked against the datasheet before it reaches the vehicle.
Do not accept a capacity figure without the rate. A “200 Ah” quoted without C3 is a 200 Ah claim at an unknown rate. Ask for the discharge curve or the test certificate.
Verify the physical tolerances. 34 kg +/- 0.2 kg and 260 x 180 x 270 mm are published. A tolerance of more than a few millimetres across a fleet makes tray machining and connector alignment inconsistent, and inconsistent trays generate vibration failures on scrubbers and AGVs.
Check the storage and shipping plan. Sealed AGM blocks ship more simply than flooded cells, but they still arrive with a partial state of charge. A supplier who documents the 12-hour initial charge, the storage temperature and the shipping interval is a supplier who has shipped these before.
Ask who handles the warranty claim in your market. A 2-5 year design life is only worth what the local claim path is worth. For distributors in Brazil, Poland, Turkey, South Africa and the Gulf, this is the single most important line in the agreement.
Do not accept a cell that arrives wet. A sealed 3-EVF-200 block has no vent to dry out and no liquid to top up. Any sign of corrosion on the terminal, or a swollen case, means the block was damaged in transit or stored at a temperature outside the published range. Reject it at the door.
§6 — FAQ
Q1. What does 200 Ah mean on the 3-EVF-200 6V200Ah, and why does the rating basis matter? It means 200 Ah at the 3-hour discharge rate with a 1.75 V per cell cutoff. A cell rated 200 Ah at the 20-hour rate gives a smaller working window in the 1-4 hour discharge pattern typical of a traction vehicle, so the two figures are not interchangeable. Ask the supplier to state the basis in the quotation.
Q2. How many 3-EVF-200 blocks make a 48 V pack, and how much does it weigh? Eight units in series. Nominal energy is 8 x 6 V x 200 Ah = 9.6 kWh and pack weight is 8 x 34 kg = 272 kg, both straight arithmetic from published figures. The published configuration band also covers 10-12 units for 60-72 V and 8-16 units for the 48-96 V range.
Q3. What charging current does the pack need? The published maximum is 40 A per block, so an eight-unit 48 V pack sits in the 320 A class and a twelve-unit 72 V pack in the 480 A class. Float is 6.75 V for the 6 V block and equalise is 7.05 V. Undersizing the charger lengthens the charge cycle and degrades the equalise stage after a deep discharge.
Q4. Can the 3-EVF-200 6V200Ah be used for a golf cart, a forklift and an AGV with the same block? The electrical case is the same, but the duty profile is not. Golf carts and sightseeing vehicles run short, high-current cycles; a 1-3 ton forklift runs longer cycles at higher mass; an AGV usually runs shallow cycles with opportunity charging. The published cycle life of 350-600 cycles at 50-80% depth of discharge is the figure you should plan against, and the depth of discharge your operation actually reaches decides whether the pack lasts two years or five.
Q5. What happens to a block that has been in storage or shipped for several months? Run the initial charge of not less than 12 hours before the vehicle enters service. A sealed AGM block recovers its surface charge quickly, so a workshop voltage check will look acceptable while the usable capacity is still low. This is a routine step for any battery that has crossed from Shanghai, Ningbo or Shenzhen through Mombasa, Lagos, Santos or Port Said.
Q6. Does it need watering, and what does maintenance-free actually cover? There is no watering. The 3-EVF-200 6V200Ah is a sealed valve-regulated AGM block with no water or acid refill over its service life. Maintenance reduces to terminal checks, cleanliness, and keeping the charge controller programmed to the published float and equalise voltages.
Q7. How does it compare with a lithium traction pack for the same vehicle? Lithium publishes 3,000-5,000 cycles at 80% depth of discharge against the 350-600 cycles published for this block at 50-80%, so a high-cycle operation will consume lead-acid packs earlier. Lithium also removes the charger and water-service infrastructure. Lead-acid wins on purchase cost, on weight per unit of volume in some classes, and on the absence of a battery management system and cell-level certification paperwork. For fleets with a technician and frequent deep cycles, compare the two over the full replacement horizon, not over the first invoice.
Q8. What operating temperature range applies, and what happens outside it? Discharge, charge and storage all sit inside a -15 °C to +50 °C window. Cold reduces charge acceptance and available capacity; heat above the ceiling shortens cycle life and accelerates self-discharge. For a vehicle parked outdoors in a non-air-conditioned bay, specify a canopy or a charger with temperature compensation rather than assuming the published window holds.
Q9. What should be in the purchase order so that a claim is honoured in two years? The model and block rating, the capacity basis (200 Ah at C3 to 1.75 V per cell), the float and equalise voltages, the maximum charging current, the operating temperature range, the applicable test standard, the design life, and the local warranty claim path with a named contact.
Expert Summary
The 3-EVF-200 6V200Ah is a 6 V, 200 Ah sealed valve-regulated AGM lead-acid block for mid-to-large electric road vehicles: 4-8 seat sightseeing vehicles, golf carts, 1-3 ton electric forklifts and stackers, floor scrubbers and sweepers, AGV robots and small electric boats. The decisive published specification is that 200 Ah is a 3-hour rate at a 1.75 V per cell cutoff, so every quotation and warranty must state the basis; a 20-hour rating for the same case describes a different cell with a shorter working window. The block measures 260 x 180 x 270 mm, 275 mm over the terminals, weighs 34 kg, carries a phi20-M8 terminal, publishes 350-600 cycles at 50-80% depth of discharge and a 2-5 year design life, floats at 6.75 V, equalises at 7.05 V, accepts a maximum of 40 A, and operates between -15 °C and +50 °C with no maintenance. Pack arithmetic is straightforward: 8 units give a 48 V bus at 9.6 kWh nominal and 272 kg, 10-12 units give 60-72 V, and 8-16 units cover the 48-96 V band, each step adding units, terminals and mass. Against lithium traction packs, which publish 3,000-5,000 cycles at 80% depth of discharge, the lead-acid choice is a cost and infrastructure decision rather than a performance one: it wins on purchase price, on the absence of watering and battery management systems, and on sites with no technician, while lithium wins decisively on cycle life in high-cycle duty. The non-negotiables before signing are the C3 basis in writing, a charger in the 320 A class for an eight-unit pack, a controller programmed to 6.75 V float and 7.05 V equalise, a temperature check against the published ceiling, a 12-hour initial charge for any new or long-stored block, and a documented local warranty path.
Contact CHISEN — 24-Hour Response
CHISEN replies to technical and commercial enquiries within 24 hours, and delivers a sizing sheet and quotation against your actual duty data.
Send us the information below and we will return a written recommendation with the published data for the block and the pack configuration that matches it:
- Vehicle type and duty cycle (how many cycles per day, depth of discharge, shift pattern)
- Bus voltage and pack configuration, or the duty you want to size
- Ambient temperature range at the deployment site
- Charger type, voltage and available output current
- Annual volume and destination port for the first shipment