OPzV2-250 2V250Ah Tubular Gel Battery — Complete Industrial Buyer’s Guide for Telecom / UPS / Solar Backup (2026)
Reading time: 18 minutes | Target audience: B2B procurement engineers, telecom power designers, solar EPC contractors, industrial distributors
Key Takeaways (TL;DR)
- OPzV2-250 2V250Ah is a 2V 250Ah tubular gel VRLA battery designed for mid-capacity backup power (telecom base stations, UPS, off-grid PV) with 20+ year float design life.
- CHISEN OPzV2-250 follows DIN 40472 + IEC 60896-21/22 standards, ships from a 100,000+ cell factory, exports to 60+ countries.
- Tubular positive plate + nano-gel electrolyte gives ≥ 1500 cycles @ 80% DOD — 1.5-2× the cycle life of flat-plate AGM at the same capacity.
- Maintenance-free (no water refill) + 48V/110V/220V/380V series compatibility cuts lifetime O&M cost 30-40% vs flooded OPzS.
- CHISEN factory-direct pricing: free selection tool, 24h quotation, OEM/ODM supported, FOB/CIF/DDP shipping to 60+ countries.
—
§1 Product Definition — What is CHISEN OPzV2-250 2V250Ah?
CHISEN OPzV2-250 is a 2V 250Ah tubular positive plate + nano gel electrolyte + valve-regulated sealed lead-acid cell, certified to IEC 60896-21/22 + DIN 40472 + GB/T 19638 standards.
Model decoding (DIN 40472 standard):
- OPz = Ortsfeste Panzerplatten (German for “stationary tubular armored plate”) — confirms tubular plate construction
- V = Valve Regulated (sealed, gel-immobilized electrolyte)
- 2 = 2V nominal cell voltage (24 cells → 48V system; 54 cells → 108V / 110V DC; 108 cells → 216V / 220V DC; 190 cells → 380V 3-phase DC)
- 250 = 250Ah rated capacity at C10 discharge rate (10-hour rate to 1.80V/cell)
Why “250Ah”? The sweet spot for mid-scale telecom and solar. 250Ah is the most-requested mid-capacity cell because it lets you build 48V systems at 250Ah (12kWh), 110V DC panels at 250Ah (27.5kWh), and 220V industrial DC at 250Ah (55kWh) — without the size/weight penalty of 500Ah+ cells and without the high cell-count cost of 100Ah cells.
Spec snapshot (CHISEN datasheet §2):
| Parameter | Value | Standard / Note |
|---|---|---|
| Nominal voltage | 2V (DC) | Single cell |
| Nominal capacity | 250Ah (C₁₀) | 10-hour rate to 1.80V/cell |
| Model | OPzV2-250 | CHISEN coding system |
| Series | Tubular GEL VRLA | Tubular plate standard scheme |
| Applicable standards | IEC 60896 + DIN 40472 + GB/T 19638 (7 standards, see §4) | International / regional / industry |
| Dimensions (L×W×H) | 124 × 206 × 354 mm | ±2 mm tolerance |
| Total height (with terminals) | 390 mm | Φ20-M8 terminal up |
| Battery weight (full electrolyte) | 20.0 kg (44.1 lbs) | ±5% with electrolyte |
| Terminal type | Φ20-M8 | Tin-plated copper |
| Terminal torque | 10-12 N·m | M8 standard torque |
| Operating temperature (discharge) | -40°C ~ 65°C | Tubular gel wider than flooded |
| Operating temperature (charge) | -30°C ~ 65°C | High-temp ceiling for tropical use |
| Operating temperature (storage) | -25°C ~ 45°C | Storage is the most restrictive |
| Float voltage | 2.25-2.27V/cell (25°C) | See §12 for compensation |
| Float temperature compensation | -3.3mV/°C/cell | Datasheet recommended |
| Equalize voltage | 2.30-2.35V/cell (25°C) | ≤ 24h, monthly |
| Equalize temperature compensation | -5mV/°C/cell | Independent of float |
| Cycle charging voltage | 2.35-2.40V/cell (25°C) | Cyclic service |
| Max charging current | 75A (0.30C₁₀) | Datasheet max allowed |
| Max discharge current (5s) | 1500A | Datasheet recommended |
| Self-discharge rate | 2% / month (storable 1 year without charge, 25°C) | 25°C storage |
| Internal resistance (full charge / 25°C) | 0.72 mΩ | Datasheet measured |
| Short-circuit current | 3200A | Protection coordination |
| Cycle life | ≥ 1500 cycles (80% DOD) | Tubular plate standard |
| Float design life | 20+ years (25°C) | Datasheet nominal |
| Transport / Sea freight | IMDG Class 8 / UN2794 / MSDS | Lead-acid battery |
—
§2 CHISEN OPzV2-250 30-Second Quick Reference
| Spec | Value | ||
|---|---|---|---|
| Model & Specs | CHISEN OPzV2-250 \ | 2V 250Ah (C10) \ | Tubular GEL VRLA Battery |
| Technology | Tubular positive plate + nano gel electrolyte + valve-regulated sealed (standards in §4) | ||
| Core Advantages | Cycle life ≥ 1500 cycles (80% DOD) / float design life 20+ years (25°C) | ||
| Typical Applications | Telecom base stations (especially unattended) + PV/Wind energy storage + medium UPS + rail signal + extreme environment float + outdoor cabinets |
—
§3 Model Naming Rules — OPzV vs OPzS vs AGM (DIN 40472 vs DIN 40736-1)
CHISEN OPzV2-250 naming follows German DIN 40472 (tubular valve-regulated gel) + international IEC 60896 standard. OPz is the German abbreviation of “Ortsfeste Panzerplatten” — meaning “stationary tubular armored plate” — confirming the tubular positive plate construction (the core of CHISEN’s > 1500 cycle life).
| Letter | German full name / meaning | Technical meaning |
|---|---|---|
| OPz | Ortsfeste Panzerplatten / Stationary tubular armored plate | Positive plate = tubular |
| V | Valve Regulated | Sealed valve-regulated / GEL |
| 2 | 2V cell voltage | 48V = 24 cells / 110V = 54 cells / 220V = 108 cells in series |
| 250 | 250Ah capacity (C10 / 10-hour rate) | Discharge to 1.80V/cell at 10-hour rate |
OPzV vs OPzS vs AGM — at a glance:
| Parameter | OPzV (CHISEN OPzV2-250) | OPzS (tubular flooded) | AGM (flat-plate VRLA) |
|---|---|---|---|
| Technology | Tubular + GEL + VRLA | Tubular + flooded + vented | Flat plate + AGM + VRLA |
| Electrolyte | Immobilized gel | Liquid sulfuric acid | AGM glass-fiber |
| Maintenance | Maintenance-free | Water refill every 3-6 months | Maintenance-free |
| Cycle life (80% DOD) | ≥ 1500 cycles | 1500-2500 cycles | 500-1000 cycles |
| Float life (25°C) | 20+ years | 20-25 years (with maintenance) | 10-15 years |
| Installation direction | Vertical / horizontal / sideways | Vertical only | Vertical / horizontal / sideways |
| Cost (relative) | Medium | Low | Low |
| Best for | Telecom / PV / unattended | Large UPS / rail / marine | Automotive / small UPS |
—
§4 CHISEN OPzV2-250 Applicable Standards (7 Standards)
CHISEN OPzV2-250 complies with the following 7 international / regional / industry standards (the product design basis). Standard compliance = sales compliance + smooth customs clearance + one-pass project bidding.
| Standard | Number | Scope |
|---|---|---|
| International IEC | IEC 60896-21/22:2004 | Stationary valve-regulated batteries — test methods + dimensions / terminals / marking |
| International IEC | IEC 61427 | Solar PV/energy storage batteries (mandatory for solar project bids) |
| German DIN | DIN 40472:2015 | Tubular valve-regulated batteries (gold standard) |
| Chinese National | GB/T 19638.1-2014 | Stationary valve-regulated batteries (market sales compliance) |
| Chinese Telecom | YD/T 1360 | Telecom operator backup power (mandatory for carrier bids) |
| European | Eurobat Long Life | European battery life classification (> 12 years float) |
| UK / North America | BS 6290 Part 4 / UL 1989 | UK / North American backup power markets |
Note: Third-party inspection certificates / destination-country special certifications (SONCAP for Nigeria / PVOC for Kenya / SASO for Saudi Arabia / BIS for India / ESMA for UAE) can be arranged per customer requirements (supported by mainstream agencies SGS / TUV / BV / CTI).
—
§5 CHISEN OPzV2-250 Physical Structure & Materials (Tubular vs Flat Plate)
CHISEN OPzV2-250’s tubular positive plate design is the core advantage (cycle life 1.5-2× higher than flat-plate batteries at the same capacity):
| Component | Material / Spec | Description |
|---|---|---|
| Positive grid | Die-cast tubular grid, Pb-Ca alloy | Fiberglass tube wraps positive active material (PbO₂) |
| Negative grid | Radial negative grid, Pb-Ca alloy | Improves active material utilization |
| Separator | Imported PVC composite separator | Low resistance / high porosity / aging-resistant |
| Electrolyte | High-purity nano gel electrolyte | SiO₂ fumed silica gel + H₂SO₄ |
| Container | High-strength ABS plastic | UL94 V-0 flame retardant |
| Cover | High-strength ABS resin | Sealed / flame retardant |
| Terminal seal | Triple seal structure | Epoxy + rubber ring + anti-leak ring |
| Safety valve | Integrated explosion-proof / acid filter | Auto pressure regulation (0.1-0.2 MPa) |
Tubular plate working principle: Fiberglass tubes completely wrap the positive active material (PbO₂), preventing active material shedding and deformation, extending deep-cycle life. This is the core design point of the DIN 40472 standard — and the reason CHISEN OPzV2-250 hits ≥ 1500 cycles @ 80% DOD.
OPzV opaque container: On-site inspection via terminal voltage + infrared temperature measurement (no need to open the cover) — perfect for unattended telecom sites.
—
§6 CHISEN OPzV Series — 18-Model Full Specification Table (100Ah-3000Ah)
CHISEN OPzV series — 18 models from 100Ah to 3000Ah (tubular gel valve-regulated / Tubular GEL VRLA). All comply with IEC 60896-21/22 + DIN 40472 + GB/T 19638.1-2014. Models in the same series can be flexibly mixed-and-matched in series to build different voltage systems (48V = 24 cells / 110V = 54 cells / 220V = 108 cells / 380V = 190 cells).
| # | Model | Capacity (C₁₀ Ah) | L (mm) | W (mm) | H (mm) | Total H (mm) | Weight (kg) | Terminal |
|---|---|---|---|---|---|---|---|---|
| 1 | OPzV2-100 | 100 | 103 | 206 | 354 | 390 | 13.0 | Φ20-M8 |
| 2 | OPzV2-150 | 150 | 103 | 206 | 354 | 390 | 15.0 | Φ20-M8 |
| 3 | OPzV2-200 | 200 | 103 | 206 | 354 | 390 | 16.5 | Φ20-M8 |
| 4 | OPzV2-250 | 250 | 124 | 206 | 354 | 390 | 20.0 | Φ20-M8 |
| 5 | OPzV2-300 | 300 | 145 | 206 | 354 | 390 | 23.0 | Φ20-M8 |
| 6 | OPzV2-350 | 350 | 124 | 206 | 471 | 506 | 26.0 | Φ20-M8 |
| 7 | OPzV2-420 | 420 | 145 | 206 | 471 | 506 | 30.0 | Φ20-M8 |
| 8 | OPzV2-500 | 500 | 166 | 206 | 471 | 506 | 34.0 | Φ20-M8 |
| 9 | OPzV2-600 | 600 | 145 | 206 | 646 | 681 | 42.0 | Φ20-M8 |
| 10 | OPzV2-700 | 700 | 254 | 210 | 471 | 506 | 52.0 | Φ20-M8 |
| 11 | OPzV2-800 | 800 | 191 | 210 | 646 | 681 | 57.0 | Φ20-M8 |
| 12 | OPzV2-1000 | 1000 | 233 | 210 | 646 | 681 | 71.0 | Φ20-M8 |
| 13 | OPzV2-1200 | 1200 | 275 | 210 | 646 | 681 | 82.0 | Φ20-M8 |
| 14 | OPzV2-1500 | 1500 | 275 | 210 | 796 | 831 | 103.0 | Φ20-M8 |
| 15 | OPzV2-2000 | 2000 | 399 | 212 | 772 | 807 | 142.0 | Φ20-M8 |
| 16 | OPzV2-2250 | 2250 | 487 | 212 | 772 | 807 | 175.0 | Φ20-M8 |
| 17 | OPzV2-2500 | 2500 | 487 | 212 | 772 | 807 | 180.0 | Φ20-M8 |
| 18 | OPzV2-3000 | 3000 | 576 | 212 | 772 | 807 | 210.0 | Φ20-M8 |
Voltage bus calculation: 48V = 24 cells in series / 110V = 54 cells / 220V = 108 cells / 380V three-phase DC = 190 cells.
—
§7 CHISEN OPzV2-250 Application Scenarios + Customer References
CHISEN OPzV2-250 is suited to the following 5 high-frequency industrial scenarios (exported to 60+ countries, applied across multiple industry projects):
1. Telecom base stations & wireless backhaul
- 4G / 5G base stations, transmission nodes, RRU remote units
- 48V 250Ah (12kWh) standard configuration for cell tower backup
- Valve-regulated maintenance-free → 40% lower OPEX vs flooded at unattended sites
2. Off-grid / grid-tied solar PV + wind hybrid systems
- Off-grid solar for telecom / villages / islands / oil-gas SCADA
- 24V/48V/110V/220V DC bus configurations
- Tubular gel withstands 80% DOD daily cycling for PV farms
3. Medium UPS for data centers & IT rooms
- Rack-level UPS for mid-sized data centers (50-500 kVA)
- Replace AGM flat-plate batteries with longer-life tubular gel
- 100,000+ cells in stock at CHISEN — immediate shipment
4. Rail signaling & metro emergency lighting
- Trackside signal backup power for passenger / freight rail
- Anti-vibration design tested to EN 50155 rail standard
- 220V DC panel with 108 cells for high-voltage rail signaling
5. Extreme environment — nuclear / desert / offshore
- Nuclear power plant EPS, desert telecom sites, offshore wind SCADA
- Wide temp range -40°C ~ 65°C, gel withstands thermal stress
- Maintenance-free = critical for unmanned hazardous sites
Real customer cases (5 international projects, covering Europe / South America / Middle East / Southeast Asia / Africa — CHISEN’s main export regions):
- Case 1 — European mobile operator, Alps 4G border unmanned base station: 5-year partnership, 48V 100Ah system, -25°C cold climate, valve-regulated maintenance-free reduces remote-site O&M cost 40%
- Case 2 — South American grid, Andes 3000m high-altitude substation: 4-year follow-up, 2V 500Ah 1000+ cells in series, extreme high-altitude temperature swings, DIN 40472 standard compliant
- Case 3 — Middle East state railway, 2500 km passenger line signal power: Desert extreme temperature -5~55°C, multi-voltage (48V/108V/220V/380V), anti-vibration design passed EN 50155
- Case 4 — Southeast Asian island EPC, off-grid solar + storage EPC: Tropical humid island 3-year follow-up, 48V 200Ah × 32 groups, salt-corrosion environment, deep cycle ≥ 1200 cycles
- Case 5 — African solar village, off-grid generation project: Sub-Saharan 50°C high temp, 24V/48V hybrid system, 4-year stable operation, valve-regulated maintenance-free for unmanned sites
—
§8 CHISEN OPzV Valve-Regulated Gel vs OPzS Tubular Flooded — 22-Dimension Comparison Table
CHISEN OPzV (valve-regulated gel) vs OPzS (flooded) — both have tubular positive plates (OPzV = DIN 40472 / OPzS = DIN 40736-1) + 20+ year float design life. Which one? Depends on 6 dimensions:
I. Core electrical parameters (10 rows):
| Parameter | OPzV Valve-Regulated Gel | OPzS Tubular Flooded |
|---|---|---|
| Type | Valve-regulated gel (VRLA GEL) | Open flooded (Vented Flooded) |
| Electrolyte | Nano silica gel (immobilized, non-flowing) | Dilute H₂SO₄ 1.24 g/cm³ (liquid) |
| Positive plate | Die-cast tubular (Pb-Ca alloy) | Die-cast tubular (Pb-Sb low-antimony) |
| Applicable DIN standard | DIN 40472:2015 (tubular valve-regulated) | DIN 40736-1:1985 (tubular flooded) |
| Container | ABS flame-retardant UL94 V-0 (opaque) | SAN transparent plastic (visible liquid level) |
| Short-circuit current (100Ah) | 1700 A | 1500 A |
| Internal resistance (20°C) | 0.0011 Ohm (1.1 mΩ) | 0.001 Ohm (1.0 mΩ) |
| Max charging current | 30 A (0.30C₁₀) | 20 A (0.20C₁₀) |
| Self-discharge rate (20°C full charge) | 2%/month | 3%/month |
| Float voltage (25°C) | 2.25-2.27V/cell | 2.24V/cell |
II. Environmental adaptability (4 rows):
| Parameter | OPzV | OPzS |
|---|---|---|
| Operating temperature (discharge) | -40°C ~ 65°C (gel heat-tolerant) | -40°C ~ 60°C |
| Operating temperature (charge) | -30°C ~ 65°C | -30°C ~ 55°C |
| Capacity at 40°C | ~105% | 108% |
| Capacity at -20°C | ~55% | ~65% (estimated) |
III. Life & cycle (4 rows):
| Parameter | OPzV | OPzS |
|---|---|---|
| Float life (25°C) | 20+ years | 20+ years (requires periodic water refill) |
| Float life (30°C) | ~10 years | 8-10 years |
| Cycle life (DOD 80%) | ≥ 1500 cycles | 1500-2500 cycles |
| Cycle life (DOD 50%) | 2200+ cycles | 2500-4000 cycles |
IV. Maintenance & installation (4 rows):
| Parameter | OPzV | OPzS |
|---|---|---|
| Water refill | Maintenance-free (no refill) | Every 3-6 months (distilled water) |
| Acid mist emission | Minimal (sealed + acid-filter valve) | More (flooded + filter vent plug) |
| Installation direction | Vertical / horizontal / sideways (not inverted) | Must be vertical (electrolyte will leak) |
| On-site inspection | Not possible (opaque container) | Possible (transparent container, visible liquid + plates) |
V. Commercial & decision (4 rows):
| Parameter | OPzV | OPzS |
|---|---|---|
| Procurement cost (relative) | Higher (+15-25% vs OPzS) | Lower (mature process) |
| Maintenance cost (20 years) | Very low (maintenance-free) | Medium (labor + distilled water) |
| TCO (20 years) | Medium (higher purchase + lower maintenance) | Lower (lower purchase + medium maintenance) |
| Recycling value | High (lead recyclable) | High (lead recyclable) |
VI. Selection decision conclusion (if you care about X → choose Y):
| Concern / Application | Recommended Choice | Reason |
|---|---|---|
| Unattended / remote / island / border base station | OPzV | Maintenance-free + any-direction install + sealed (40% O&M savings) |
| Tropical / desert / extreme high-temp environment (>45°C continuous) | OPzV | Gel heat-tolerant (charge -30~65°C vs OPzS -30~55°C) |
| Deep cycle (PV daily 1 cycle @ 80% DOD) | OPzS | 50% longer cycle life (2500 vs 1500 cycles) |
| Large UPS data center (>500 kVA high-rate) | OPzS | Longer deep-cycle life (1500-2500) + large capacity (2000+ Ah) reduces series count |
| Mobile / tilt installation / automotive | OPzV | Any-direction install (sealed, no leak) |
| Transparent visual inspection / on-site maintenance (manned station regular inspection) | OPzS | SAN transparent container + filter vent plug (visible maintenance + acid-mist filtration) |
Selection takeaway for OPzV2-250: OPzV2-250 is the best fit for telecom base stations, unattended PV sites, and remote industrial applications where maintenance-free operation + any-direction installation + wide temperature range are the primary selection criteria. For high-cycle solar farms or large data centers with regular maintenance, OPzS may be preferred.
—
§9 Selection Decision Table — OPzV / OPzS / AGM Comparison
CHISEN OPzV2-250 / OPzS / AGM three lead-acid types in large industrial energy storage and backup power scenarios, with selection recommendations:
Selection decision table (if your application is X → recommended Y):
- Data center UPS / 5G base station / PV energy storage / unattended / remote deployment → OPzV (tubular gel valve-regulated, maintenance-free + any-direction install)
- Large data center UPS (>500 kVA) / rail signal / emergency lighting / ship main control / manned机房 → OPzS (flooded, longer life + lower cost + higher short-circuit current)
- Auto starting / e-bike / motorcycle / small UPS / short backup (<30 min) → AGM flat-plate (lowest cost)
| Comparison | OPzV (tubular gel VRLA) | OPzS (tubular flooded) | AGM (flat-plate VRLA) |
|---|---|---|---|
| Positive plate structure | Tubular | Tubular | Flat plate |
| Electrolyte | Nano gel (GEL) | Dilute H₂SO₄ (flooded) | AGM glass fiber |
| Valve-regulated | Yes (sealed) | No (open + vent plug) | Yes (sealed) |
| Maintenance-free | Yes | Water refill (3-6 months) | Yes |
| Cycle life (80% DOD) | ≥ 1500 cycles | 1500-2500 cycles | 500-1000 cycles |
| High-rate discharge capability | Strong (1500-1700A) | Medium (1500-1600A) | Medium (800-1500A) |
| Installation direction | Vertical/horizontal/sideways | Vertical only | Vertical/horizontal/sideways |
| Typical application | UPS / base station / PV / unattended | Large UPS / rail / ship / emergency | Auto starting / small UPS / e-bike |
| Relative price | Medium | Low | Low |
| Environmental compliance | RoHS / REACH / WEEE | RoHS / REACH / WEEE | RoHS / REACH / WEEE |
—
§10 CHISEN OPzV2-250 Capacity Sizing Formula + Solar / Wind Configuration Parameters
Battery capacity (Ah) = Load power (W) × Backup time (h) ÷ Bus voltage (V) ÷ Inverter efficiency ÷ Temperature coefficient
Where: inverter efficiency UPS 0.85 / DC load 1.0; temperature coefficient 25°C = 1.0 / 35°C = 0.85 / 45°C = 0.70 (high-temp derating); recommend 20-30% margin.
Example 1 — Telecom base station 48V system, 4-8h backup before generator switch. Load 1 kW, backup 4h, bus 48V, efficiency 0.85, temp 25°C. Capacity = 1000 × 4 ÷ 48 ÷ 0.85 ÷ 1.0 ≈ 98Ah. Recommended: OPzV2-100 (24 cells series for 48V), 2% margin.
Example 2 — Off-grid solar 5kW system, 4h backup. Load 5 kW, backup 4h, bus 48V, efficiency 0.85, temp 25°C. Capacity = 5000 × 4 ÷ 48 ÷ 0.85 ÷ 1.0 ≈ 490Ah. Recommended: OPzV2-500 (24 cells series for 48V), 2% margin.
Example 3 — 110V DC panel, 10h backup. Load 0.5 kW, backup 10h, bus 110V, efficiency 1.0 (DC load), temp 25°C. Capacity = 500 × 10 ÷ 110 ÷ 1.0 ÷ 1.0 ≈ 45Ah. Recommended: OPzV2-100 (54 cells series for 108V), 100% margin.
Example 4 — 220V three-phase DC industrial power, 30 min full-load backup. Load 100 kW, backup 0.5h, bus 220V, efficiency 1.0, temp 25°C. Capacity = 100000 × 0.5 ÷ 220 ÷ 1.0 ÷ 1.0 ≈ 227Ah. Recommended: OPzV2-250 (108 cells series for 220V), 10% margin. ← OPzV2-250 is the perfect fit here.
Example 5 — Telecom base station 48V system, 1kW load, 8h backup. Capacity = 1000 × 8 ÷ 48 ÷ 0.85 ÷ 1.0 ≈ 196Ah. Recommended: OPzV2-200 (24 cells series), 4% margin.
More series configurations: 48V = 24 cells / 110V = 54 cells / 220V = 108 cells / 380V = 190 cells — detailed in §7 application scenarios.
Solar / wind system application configuration parameters (CHISEN datasheet p1 measured):
| Parameter | Setpoint | Description |
|---|---|---|
| Over voltage disconnect | 2.45 ± 0.01V/cell @25°C | Charge complete / PV controller disconnects battery |
| Regulation / equalize voltage | 2.40 ± 0.01V/cell @25°C | Periodic equalization, every 30-60 days |
| Solar array reconnect voltage | 2.25 ± 0.005V/cell @25°C | Reconnect after float recovery |
| Float voltage setting | 2.27 ± 0.005V/cell @25°C | Stable state for PV off-grid |
| Low voltage alarm | 1.95 ± 0.005V/cell @25°C | Warning that load is about to disconnect |
| Low voltage disconnect | 1.90 ± 0.005V/cell @25°C | Disconnect load to protect battery from over-discharge |
| Load reconnect voltage | 2.09 ± 0.01V/cell @25°C | Reconnect load after over-discharge recovery |
| Temperature compensation coefficient | -3 ~ -5 mV/°C/cell | Float -3.3mV, equalize -5mV |
Free engineering sizing: Email “system voltage + load power + backup time + operating temperature” to sales@chisen.cn, receive complete Excel sizing sheet + quotation within 24h.
5-Step Sizing Methodology
- Step 1 — Confirm system voltage + series count: Telecom base station / PV / UPS / rail / medical / ship → 24 cells series (48V system) / 54 cells series (108V compatible with 110V DC panel) / 108 cells series (216V compatible with 220V industrial power) / 190 cells series (380V three-phase DC data center UPS)
- Step 2 — Select capacity: Use “battery capacity = load power × backup time ÷ bus voltage ÷ inverter efficiency ÷ temperature coefficient” formula → select closest standard capacity (100/200/300/500/1000/1500/2000/3000 Ah), 20-30% margin
- Step 3 — Verify cycle life + battery type: Float backup (base station / UPS) → OPzV (maintenance-free 20+ years); deep cycle (PV daily) → OPzV or OPzS (tubular ≥1500 cycles); high current (data center UPS > 500 kVA) → OPzS (short-circuit 1500A+)
- Step 4 — Check dimensions + weight: OPzV2-250 dimensions 124×206×354mm / weight 20.0kg (with electrolyte); battery cabinet / rack reserve ≥ 50mm heat dissipation spacing
- Step 5 — Select after-sales + certification: Project bidding / customs clearance requires destination-country standards (see §4); recommend CHISEN (20+ year brand + 60+ country export experience + on-demand destination-country certification assistance)
—
§11 CHISEN OPzV2-250 Cycle Life Detail + 20-Year TCO Comparison (Tubular vs AGM)
CHISEN OPzV2-250 cycle life ≥ 1500 cycles @ 80% DOD (IEC 60896-21 standard test conditions, 25°C). The tubular positive plate design is the core advantage — at the same capacity, cycle life is 1.5-2× longer than flat-plate batteries.
Tubular vs Flat-plate cycle life comparison (DIN 40472 + measured):
| DOD | Tubular (CHISEN OPzV2-250) | Flat-plate (AGM) | Life difference |
|---|---|---|---|
| 80% DOD (deep cycle) | 1500-2500 cycles | 500-1000 cycles | ×1.5-2.5 |
| 50% DOD (medium cycle) | 2200-3500 cycles | 750-1500 cycles | ×2-3 |
| 30% DOD (shallow cycle) | 3500-6500 cycles | 1500-3000 cycles | ×2-3 |
| Float standby (no cycle) | 20+ years (25°C) | 10-15 years (25°C) | ×1.5-2 |
CHISEN OPzV cycle life vs DOD precision curve (datasheet measured, 25°C, float 2.23V/cell, IEC 60896-21 test conditions):
| DOD | Cycle Life | Application | Corresponding years (1 cycle/day) |
|---|---|---|---|
| 20% DOD | 5500 cycles | UPS pulse discharge / telecom frequent switch | 15+ years |
| 30% DOD | 4000 cycles | Shallow cycle emergency / partial backup | 11+ years |
| 50% DOD | 2500 cycles | Medium cycle / solar off-grid | 7+ years |
| 80% DOD | ≥ 1500 cycles (nominal) | Deep cycle (OPzV nominal / datasheet measured 1300 cycles) | 3.5+ years |
| 100% DOD | 800 cycles | Full discharge (emergency condition) | 2+ years |
20-Year TCO comparison for typical 48V 250Ah backup system:
| Cost item | OPzV Tubular Gel VRLA (CHISEN) | OPzS Tubular Flooded (CHISEN) | AGM Flat-plate VRLA |
|---|---|---|---|
| Initial purchase cost (incl. install) | Medium (tubular gel) | Lower (tubular flooded / mature process) | Lowest (flat-plate VRLA) |
| Design life | 20+ years (25°C float) | 20-25 years (25°C float, periodic maintenance) | 8-12 years (25°C float) |
| Replacements needed in 20 years | 0 (one purchase, lifetime use) | 0 (with good maintenance) | 1-2 (around year 8 / year 16) |
| Annual maintenance cost | Very low (maintenance-free, just cleaning) | Medium (water refill every 3-6 months + cleaning) | Medium (voltage monitoring + cleaning) |
| 20-year TCO | Medium (medium purchase + low maintenance) | Lower (low purchase + medium maintenance) | High (low purchase but short life = multiple replacements) |
B2B key conclusion: Tubular batteries have initial cost ~1.5-2× higher than AGM flat-plate, but last 2× longer, and 20-year TCO is 30-40% lower than AGM — making OPzV2-250 a clear long-term win for telecom / solar projects with 15+ year operating horizons.
—
§12 CHISEN OPzV2-250 Float Voltage Setting + Temperature Compensation Formula
CHISEN OPzV2-250 standard float voltage is 2.25-2.27V/cell (25°C, with -5mV/°C independent equalize compensation), and requires float temperature compensation -3.3mV/°C/cell.
Float voltage temperature compensation formula (IEC 60896-21:2004):
V_float (actual temperature) = 2.27V + (-3.3mV/°C) × (actual temperature - 25°C)
| Ambient temperature | Calculation | Compensated float voltage |
|---|---|---|
| 25°C (reference) | 2.27V (no compensation) | 2.25-2.27V |
| 15°C | 2.27 + (-3.3mV × -10) | 2.30V |
| 35°C | 2.27 + (-3.3mV × 10) | 2.24V |
| 45°C | 2.27 + (-3.3mV × 20) | 2.20V |
Operation scenario recommendations:
- Cold region (winter -20~0°C ambient): Float compensation 2.25-2.30V/cell — too low will be unbalanced, recommend higher compensation -5mV/°C
- Standard机房 (15-30°C): Float 2.25-2.27V/cell no compensation (factory default 25°C)
- Hot region (tropical / desert 30-50°C): Float 2.20-2.23V/cell with -3.3mV/°C compensation — high temp = float voltage to drop, otherwise accelerate grid corrosion
- Telecom base station outdoor cabinet: with intelligent temperature compensation controller (most UPS / solar controllers support)
—
§13 CHISEN Factory Capability & Certifications — Why B2B Buyers Choose CHISEN
Factory capability (verified):
| Indicator | Data |
|---|---|
| Production base | 8 factories (China) |
| Annual capacity | 70 million kVAh (lead-acid + lithium combined) |
| Service years | 20+ years (since 2003) |
| CHISEN OPzV cell stock | 100,000+ cells ready to ship |
| Export countries | 60+ countries |
| Third-party testing agencies cooperation | SGS / TUV / BV / CTI |
| Product series | Lead-acid (OPzV/OPzS/AGM/GEL/Front-terminal) + Lithium (LiFePO4) + Solar energy storage |
| Production line certification | ISO 9001 + ISO 14001 + OHSAS 18001 |
| Product certification | CE / IEC / UL / ISO 9001 (can apply for SONCAP/PVOC/SASO/BIS/ESMA per destination) |
CHISEN customer reference (highlights, 60+ countries):
- European telecom operator — 5-year partnership (continuous replenishment)
- Middle East state railway — 2500 km passenger line backup power project (flagship)
- South American grid — Andes 3000m high-altitude substation (extreme environment)
- Southeast Asian island EPC — off-grid solar storage system (climate adaptation)
- African solar village — Sub-Saharan high-temp off-grid project (maintenance-free)
Why B2B buyers choose CHISEN (4 reasons):
- Factory-direct pricing — 8 production bases + 70 million kVAh capacity, no middlemen, factory-direct pricing better than market average 15-25%
- 60+ country export experience — destination-country certifications (SONCAP / PVOC / SASO / BIS / ESMA) handled in one stop, customs clearance smooth
- 24h quote + free selection — Send inquiry, receive complete Excel sizing sheet + factory-direct quotation within 24h
- Full after-sales + OEM/ODM — 3-year warranty + on-site guidance + OEM/ODM customization + spare parts supply
—
§14 Frequently Asked Questions (FAQ) — 6 Q&A for CHISEN OPzV2-250
Q1: What’s the difference between CHISEN OPzV2-250 and OPzS2-250?
A: Both are tubular plate batteries, capacity 250Ah, same dimensions 124×206×354mm. Main difference is electrolyte and maintenance:
- OPzV2-250 = Tubular + nano gel electrolyte + valve-regulated sealed (VRLA), maintenance-free, any-direction install, float life 20+ years, no water refill
- OPzS2-250 = Tubular + dilute H₂SO₄ electrolyte + open vented (flooded), needs water refill every 3-6 months, must be vertical, float life 20-25 years (with maintenance), 50% longer cycle life (1500-2500 cycles vs OPzV ≥1500)
Selection: If unmanned / remote / island / border / desert / automotive applications → OPzV2-250 (maintenance-free). If large data center UPS (>500 kVA) / rail signal / deep cycle solar (>1200 cycles/year) / manned机房 with regular maintenance → OPzS2-250.
Q2: How many OPzV2-250 cells are needed to make a 48V/110V/220V/380V system?
A: Voltage bus = 2V × series cells:
- 48V system: 24 cells in series (e.g., 24 × OPzV2-250 → 48V 250Ah / 12kWh)
- 110V DC panel (108V): 54 cells in series (54 × OPzV2-250 → 108V 250Ah / 27kWh)
- 220V industrial power (216V): 108 cells in series (108 × OPzV2-250 → 216V 250Ah / 54kWh)
- 380V three-phase DC: 190 cells in series (190 × OPzV2-250 → 380V 250Ah / 95kWh)
To increase capacity (Ah), add cells in parallel (e.g., 24S2P → 48V 500Ah). Contact CHISEN engineering team for system design + cabinet / rack customization.
Q3: Does CHISEN OPzV2-250 support OEM/ODM customization?
A: Yes. CHISEN supports OEM/ODM:
- OEM: Your brand label + packaging (custom brand > 200 cells)
- ODM: Custom capacity / dimensions / terminal / voltage / case color (needs project evaluation, MOQ 500 cells)
- Project customization: Special certifications (UL / SONCAP / SASO) and special destination-country marking supported
Lead time: Standard 7-15 days for shipment; OEM 15-25 days; ODM 30-45 days.
Q4: What’s the cycle life of OPzV2-250? How to maximize it?
A: Datasheet nominal ≥ 1500 cycles @ 80% DOD (IEC 60896-21 test conditions, 25°C). To maximize life:
- Operating temperature: Stay at 25°C ideal, derating above 35°C (high temp accelerates grid corrosion)
- Float voltage: Strictly follow 2.25-2.27V/cell (25°C), with temperature compensation -3.3mV/°C
- Discharge depth: Avoid >80% DOD, recommended working range 30-70% DOD
- Charging current: Limit to ≤ 0.30C₁₀ (i.e., ≤ 75A for OPzV2-250), do not exceed datasheet max
- Equalize charging: Monthly equalize charge (2.30-2.35V/cell) ≤ 24h, re-balances cells
- Avoid over-discharge: Set low-voltage disconnect at 1.90V/cell (protect from deep over-discharge)
Q5: What’s the warranty? How to claim?
A: CHISEN OPzV2-250 standard warranty is 3 years (from B/L date). Warranty scope:
- Cover: Manufacturing defects / container cracking / premature capacity loss (<80% nominal within 3 years)
- Not cover: Over-discharge / over-charge / physical damage / unauthorized modification / improper operating environment
Claim procedure: Email warranty claim + battery serial number + photos + test data → sales@chisen.cn. CHISEN replies within 48h with replacement / repair / credit solution.
Q6: What’s the FOB price and lead time for OPzV2-250?
A: CHISEN OPzV2-250 factory-direct pricing tier:
- 1-50 cells: FOB Ningbo USD 145-160/cell (small order volume)
- 50-200 cells: FOB Ningbo USD 125-140/cell (medium order)
- 200+ cells: FOB Ningbo USD 105-120/cell (bulk order, contact for special pricing)
- 1000+ cells: Project-specific pricing (includes destination-country certification + OEM label)
Lead time: Standard stock 7-15 days for shipment; OEM/ODM 15-25 days; large project 30-45 days. CIF / DDP / DAP / FOB / EXW flexible trade terms.
—
§15 Expert Summary — CHISEN Senior Battery Engineer’s 5-Point Buying Advice
As a CHISEN senior battery engineer with 20+ years of lead-acid battery experience, here are my 5 key buying recommendations for OPzV2-250:
- Define application scenario first — Telecom base station / off-grid solar / mid-UPS → OPzV (gel); large UPS / rail signal / deep-cycle PV → OPzS (flooded); starting battery / small UPS → AGM. Don’t over-spec, don’t under-spec.
- Voltage bus drives series count — 48V = 24 cells / 110V = 54 cells / 220V = 108 cells / 380V = 190 cells. Series more than 24 cells → recommend single-cell consistency verification, ensure parallel capacity balance.
- Plan for 20-year lifetime, not 5-year — OPzV2-250 has 20+ year float life. Choose series-parallel topology + space + mast ladder + cable + monitoring channels consistent with 20-year operation. Avoid “first cheap, later expensive” trap (cheap purchase + multiple replacements).
- Procure from factory-direct (CHISEN) — 8 factories + 70 million kVAh capacity + 60+ country export experience + 24h quote + 3-year warranty + destination-country certification assistance. Factory-direct pricing 15-25% below market average.
—
§16 Call to Action — Get Free Sizing & Quotation
Ready to spec CHISEN OPzV2-250 2V250Ah for your telecom base station / solar project / UPS / industrial backup? Contact CHISEN engineering team:
- Email: sales@chisen.cn
- WhatsApp / Phone: +86 131 6622 6999
- WhatsApp quick chat: wa.me/8613166226999
- Website: www.chisen.cn
Free services:
- Free sizing sheet — Send “system voltage + load power + backup time + operating temperature” → receive complete Excel sizing sheet within 24h
- Free factory-direct quotation — FOB/CIF/DDP/DAP all-inclusive pricing, 24h reply
- Free OEM/ODM evaluation — Custom brand + custom specifications, project evaluation within 48h
- Free destination-country certification — SONCAP/PVOC/SASO/BIS/ESMA, handled by SGS/TUV/BV/CTI
- Free on-site installation guidance — Large project on-site commissioning (project-specific)
CHISEN Brand Promise:
- 20+ year lead-acid battery brand (since 2003)
- 8 factories + 70 million kVAh annual capacity
- 60+ country export experience
- CE / IEC / UL / ISO 9001 / ISO 14001 / OHSAS 18001 certified
- 3-year warranty + global after-sales network
Don’t wait — buyers who contact CHISEN engineering team first get the technical evaluation + production priority + competitive pricing advantage.
—
About CHISEN Battery (CHISEN Battery Co., Ltd.)
Founded 2003, headquartered in Hangzhou, China. CHISEN is a professional industrial lead-acid battery + lithium battery + solar energy storage manufacturer with 8 production bases and 70 million kVAh annual capacity. Products export to 60+ countries covering telecom, UPS, solar, rail, ship, e-bike, emergency lighting, and industrial power backup. Visit www.chisen.cn for the complete product catalog + datasheets + case studies.
Related Products:
- CHISEN OPzV2-200 (2V 200Ah) — slightly smaller capacity for smaller systems
- CHISEN OPzV2-300 (2V 300Ah) — slightly larger capacity for higher-load sites
- CHISEN OPzV2-500 (2V 500Ah) — large UPS + substation DC for high-power systems
- CHISEN OPzV2-1000 (2V 1000Ah) — large solar farm + large data center backup
- CHISEN OPzV2-1500 (2V 1500Ah) — large solar farm + offshore wind + rail signal
- CHISEN OPzV2-2000 (2V 2000Ah) — bulk energy storage + substation main backup
Related Categories:
- Lead-acid battery (Tubular GEL VRLA / OPzS Tubular Flooded / AGM VRLA / Front-terminal)
- Lithium battery (LiFePO4)
- Solar energy storage system (PV inverter + LiFePO4 battery pack)
- E-bike battery (6-DZF-12 / 6-DZF-20 / 6-DMF-32)
- Telecom backup power (48V / 110V / 220V / 380V DC panels)
—
Document version: 2026-09-28 | CHISEN Battery Co., Ltd. | www.chisen.cn | sales@chisen.cn | +86 131 6622 6999